Model APGT43.100, APGT43.160 Absolute Pressure Gauge

Brand: WIKA Alexander Wiegand SE & Co. KG

The model APGT43 intelliGAUGE® (patent, property right: e.g. DE 202007019025) can be used wherever pressure measurement has to be independent of fluctuations in the atmospheric pressure. 

The instrument serves for the on-site display with a simultaneous signal transmission to a central control or remote centre.
Features
  • No configuration necessary due to “plug-and-play”.
  • Scale ranges from 0 … 25 mbar absolute pressure.
  • Easy-to-read Analog display with nominal sizes 100 and 160.
  • High overload safety, long service life due to metallic media chamber sealing.
  • Media chamber protected against unauthorised access.

Specifications

Design

  • Mechanical Absolute Pressure Measuring instrument per DIN 16002

Nominal Size in mm

  • 160
  • 100

Accuracy Class

  • The measurement accuracy is ensured for ambient Pressure fluctuations between 955 and 1,065 mbar (Min. and Max. of atmospheric Pressure)
  • Option: 1.6
  • 2.5

Scale Ranges

  • 0 to 25 mbar to 0 to 25 bar Absolute Pressure [0 to 0.36 psi to 0 to 3,600 psi Absolute Pressure]

Scale

  • Option: Dual Scale
  • Single scale

Pressure Limitation

  • Fluctuating: 0.9 x Full Scale Value
  • Steady: Full Scale Value

Overload Safety

  • Option: 20 x Full Scale Value, Max. 25 bar Absolute Pressure, min. 1 bar Absolute Pressure
  • 10 x Full Scale Value, Max. 25 bar Absolute Pressure, min. 1 bar Absolute Pressure

Process Connection with Lower Measuring Flange

  • Further threaded Connections and open Connecting Flanges on Request
  • Small Flange for vacuum applications DN 16
  • Small Flange for vacuum applications DN 10
  • Open Connecting Flange DN 25 PN 25, DIN 2501, Form D per DIN 2526
  • Open Connecting Flange DN 25 PN 25 per EN 1092-1, Form B
  • 1/2” NPT Female
  • 1/2” NPT
  • G 1/2 B

Permissible Temperature

  • Option: -40° to +60° C (Silicone oil filling)
  • AmbientL: -20° to +60° C [-4° to 140° F]
  • Option: +200° C [+392° F] Max.
  • Medium: +100° C [+212° F] Max.

Temperature Effect

  • When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.8 %/10 K of Full Scale Value

Case

  • Safety version S3 per EN 837: with solid baffle wall (Solidfront) and blow-out back instruments with liquid filling with compensating valve to vent case

Case Filling

  • Without
  • Option: with Silicone oil M50 Case filling, ingress Protection IP65

  • Acquisition and display of processes
  • Output signals 4 ... 20 mA, 0 ... 20 mA, 0 ... 10 V for the transmission of process values to the control room
  • Pressure measurement independent of fluctuations in the atmospheric pressure
  • Monitoring of vacuum pumps and packing machines
  • Measurement of condensation pressures and determination of vapour pressure in liquids

Documentation