Series P1 Brass Flow Switch

Brand: Dwyer Instruments, LLC

The Series P1 Brass Flow Switches utilizes a piston-type design for accurate detection of excessive or insufficient liquid flow rates.

The switches have preset actuation points from 0.10 to 1.5 GPM for liquid flow.
Features
  • Piston-type operation yields accurate detection of low flow rates
  • The piston magnetically actuates a hermetically sealed SPST reed switch

Models matching criteria: 6
DWYER Brass Flow Switch, Actuation Set Point 0.10 GPM (.38 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 0.10 GPM (0.38 L/min)
100+ In Stock
$1,838.00 CAD
Does not ship to OH, United States
DWYER Brass Flow Switch, Actuation Set Point 0.75 GPM (2.84 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 0.75 GPM (2.84 L/min)
100+ In Stock
$1,232.00 CAD
Does not ship to OH, United States
DWYER Brass Flow Switch, Actuation Set Point 1.00 GPM (3.79 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 1.0 GPM (3.79 L/min)
100+ In Stock
$1,976.00 CAD
Does not ship to OH, United States
DWYER Brass Flow Switch, Actuation Set Point 0.25 GPM (.95 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 0.25 GPM (0.95 L/min)
50+ In Stock
$2,175.00 CAD
Does not ship to OH, United States
DWYER Brass Flow Switch, Actuation Set Point 1.50 GPM (5.68 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 1.5 GPM (5.68 L/min)
25+ In Stock
$1,384.00 CAD
Does not ship to OH, United States
DWYER Brass Flow Switch, Actuation Set Point 0.50 GPM (1.89 LPM), Calibrated for Water @ Standard Conditions. view more
  • Flow Rate - 0.50 GPM (1.89 L/min)
13 In Stock
$1,553.00 CAD
Does not ship to OH, United States

Specifications

Accuracy

  • ± 10 % of Set Point

Applications

  • Assuring Proper Coolant Flow in Semiconductor Processing
  • Detecting Loss of Fluid in Hydraulic Systems
  • Industrial Cleaning Equipment

Approvals & Certifications

  • CE

Electrical Connectors

  • 18 AWG 24” (60.96 cm), Polymeric Lead Wires

Electrical Rating

  • 0.06 A at 240 Vdc
  • 0.08 A at 240 Vac
  • 0.13 A at 120 Vdc
  • 0.17 A at 120 Vac

Enclosure, Body Material

  • Brass

Filter

  • 50 microns

Flow Rate

  • 0.10 to 1.50 gpm (0.38 to 5.68 LPM)

Media

  • Compatible Liquids

Mounting Position

  • Any Orientation

NPT Connection

  • 1/4” NPT Female

O-Ring Material

  • Fluoroelastomer

Piston Material

  • Polysulfone

Repeatability

  • ± 1 %

Spring Material

  • 316 Stainless Steel

Supply Pressure

  • psig: 1,000 (kPa: 6,895, bar: 68.95)

Switch Type

  • SPDT

Temperature Range

  • -29° to 107° C (-20° to 225° F)

Wetted Materials

  • Epoxy

  • Industrial Cleaning Equipment
  • Detecting Loss of Fluid in Hydraulic Systems
  • Assuring Proper Coolant Flow in Semiconductor Processing
show more