Accuracy Specifications
- ± 2.5 % at ambient Temperature -20 … +60° C and with calibration Pressure in accordance with reference isochor (Reference diagram KALI-Chemie AG, Hannover, prepared by Dr. Döring 1979)
Scale Range
- Vacuum and overpressure Range with measuring Span of 1.6 ... 16 bar (with an ambient Temperature of 20° C and gaseous phase)
Permissible Ambient Temperature
- Storage: -40° to 60° C (-40° to 140° F)
- Operation: -20° to 60° C (-4° to 140° F)
Process Connection
- Stainless Steel, Spanner flats 22 mm
- G 1/2 B per EN 837, Lower Mount
Pressure Element
- Test method: Helium mass spectrometry
- Gas-tight: leak rate ≤ 1 · 10-8 mbar · l / s
- Stainless Steel, welded
Movement
- Bimetal link (Temperature Compensation)
- Stainless Steel
Dial
- The scale Range is subdivided into Red, Yellow and Green Ranges
- Aluminium
Case
- Test method: Helium mass spectrometry
- Gas-tight: leak rate ≤ 1 · 10-5 mbar · l / s
- Stainless Steel, with gas filling
Permissible Humidity
- ≤ 90 % Relative Humidity, Non-Condensing