Brand: DanfossThe INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially designed for heating, cooling or combined heating/cooling application in local and district energy systems.
The INFOCAL 8 has been approved according to MID.
Features- Lithium battery with lifetime typical 11 years or 16 years optional (depending on selected functionality and connected flow sensor)
- Pair of Pt 500 temperature sensors included
- Temperature range: 0° to 180° C
- Power save mode
- NOWA test capability
- Connection possibility of 2- and 4-wire temperature sensor pairs
- Remote reading via M-Bus, L-Bus, RS 232, RS 485, Radio or optical interface
- Integrated Radio 868 MHz, Open Metering Standard (OMS)
- Individual remote reading (Automatic Meter Reading) with add on modules Plug & Play
- 3 communication ports (e.g. M-Bus + pulse input + radio)
- Improved radio performance
- Individual tariff functions
- History memory for 24 months
- Extensive diagnostic displays
- Dedicated district energy application telegram
- Suitable for Danfoss ECL Comfort controller and ECL 310 internet portal connection
- IZAR@SET parameterization software on Windows basis guarantees optimum adaptation to the user's specific needs
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 18
- Application - Heating
- Model - 087G1307
100+ In Stock
$2,312.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8007
100+ In Stock
$283.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8002
100+ In Stock
$98.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6221
50+ In Stock
$978.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8003
50+ In Stock
$2,102.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8006
50+ In Stock
$219.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G1324
50+ In Stock
$1,980.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6222
50+ In Stock
$1,305.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8004
50+ In Stock
$1,164.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G1311
50+ In Stock
$2,097.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8005
50+ In Stock
$1,364.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6219
50+ In Stock
$2,122.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6220
50+ In Stock
$91.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8001
50+ In Stock
$2,443.00
CAD
Does not ship to OH, United States
- Application - Heating / Cooling
- Model - 187F8000
25+ In Stock
$453.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6218
25+ In Stock
$428.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G1308
22 In Stock
$600.00
CAD
Does not ship to OH, United States
- Application - Heating
- Model - 087G6217
18 In Stock
$2,362.00
CAD
Does not ship to OH, United States
Specifications
Brand
Applications
- Chilled Water Application
- Combined Heating / Cooling Application
- District Heating / Boiler Application
Approvals & Certifications
- EN 13757-3
Cable Length
- 6.23 to 16.07 feet (1.9 to 4.9 metres)
- Temperature Sensors: 6.5 to 32.8” (2 to 10 metres)
Communication
- M-Bus
- RS-232
- RS-485
Current
- Sensor Current: Pt500 Peak< 2 mA
- Sensor Current: RMS < 0.012 mA
Diameter
- Temperature Sensor: 0.2” (5.2 mm)
- Temperature Sensor: 0.23” (6 mm)
Display
- 8-Digit LCD
- LCD Display
Environmental Protection
- IP54
Flow Rate
- LIMIT Resolution: 100 L/hr
- Nominal Flow Rate Range of Flow Sensor: 0.6 to 7,600 m³/hour
Frequency
- Frequency Band: 868 MHz
Humidity
- Maximum
Interval Time
- Sending Interval: 12 to 20 seconds
Operating Temperature
- 5° to 55° C (41° to 131° F) (> 35, Max.)
Output
- Analog Output: 4-20 mA
Power
- LIMIT Resolution: 1 KW
- LIMIT: 1 to 255 KW
Pulse Range
- Minimum Pulse Duration: 10 milliseconds With, Max.
Resistance
- Input Resistance: 2.2 megaohms
Resolution
- 1° C - LIMIT Resolution for Temperature Difference, Negative Temperature Difference, Low Temperature, High Temperature
RTD Type
- Pt 500 with 2 or 4-Wire Leads
- Pt500 with 2 or 4-Wire Leads
Storage Temperature
- -25° to 60° C (-13° to 140° F) (> 35, Max.
Supply Voltage
- Battery Supply: 3.6 Vdc (A Cell - 11-Years Lifetime & D Cell - 16 Years Lifetime)
- Mains Supply: 230 Vac / 0.15 W
- Mains Supply: 24 Vac
Temperature Range
- 1° to 255° C (33.8° to 491° F) - LIMIT for Temperature Difference, Negative Temperature Difference, Low Temperature, High Temperature
- Cooling Temperature Measuring Range: 0° to 90° C (32° to 194° F)
- Heat/Cooling Temperature Measuring Range: 0° to 105° C (32° to 221° F)
- Heating Temperature Measuring Range: 0° to 180° C (32° to 356° F)
Terminal Voltage
- 3 Vdc
- Heating, cooling or combined heating/cooling application