Price
$796.00 CAD
Stock
25+ In Stock

  • Pressure Type - Inches WC
  • Pressure Range - Inches WC: 0 to 30
  • Cover - Blind
  • Process Connection - 1/8” Female NPT Brass Port
  • Overpressure Plug - None Required

Specifications

Accuracy

  • ± 0.5 % of Full Scale (The Effects of Linearity, Hysteresis & Repeatability, are included)

Approvals & Certifications

  • ATEX Approved Products from Comhas with ECN: BVI 14-ATEX-0072
  • CE 1370 II2 GD Ex d IIC Gb T6, -60° C ≤ Ta ≤ +60° C Ex Tb IIIC Db T 85° C

Compensated Temperature

  • 0° to 48.9° C (32° to 120° F)

Connection Material

  • Brass
  • Stainless Steel

Consumption

  • DC: 38 mA - Max.

Cover Material

  • Glass Cover

Electrical Connectors

  • Screw Typical Terminal Block
  • Two 1/2” NPT Female

Enclosure Finish

  • Texture Epoxy Coat RAL7038

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • IP65 with Option OPV
  • IP66

Loop Resistance

  • 0 to 1250 ohms, Max.

Media

  • Air
  • Non-Combustible & Compatible Gases

NPT Connection

  • 1/2” NPT Female
  • 1/8” NPT Female

Output

  • 4-20 mA

Power Requirement

  • 10 to 35 Vdc (2-Wire)

Pressure Range

  • Inches WC: 0 to 50
  • Pa: 0 to 500

Pressure Type

  • Gauge

Sensor Orientation

  • Diaphragm in Vertical Position

Size

  • Dial: 4” (100 mm)

Span & Zero Adjustments

  • Protected Potentiometers

Stability

  • ± 1 % of Full Scale Per Year

Temperature Effect

  • ± 0.025 % of Full Scale/°F (0.045 % of Full Scale/°C)

Temperature Range

  • -60° to 60° C (-76° to 140° F)
show more