Series 2900 Current to Pressure Transducer

Brand: Dwyer Instruments, LLC

The Series 2900 Current to Pressure Transducer delivers reliable high performance for the toughest applications in the most hazardous environments.

Its NEMA 4X housing is designed and FM and CSA approved for both intrinsically safe and explosion-proof operation. This unit has advanced circuitry which includes electronic feedback control for superior vibration protection and highly accurate output. 

The 2900 is not position sensitive and the easily accessible zero and span adjustments make field calibration quick and easy. For ease of installation, this model has input and output ports on both the front and back. It is also not vibration sensitive, which makes the 2900 ideal for field mounting on a valve. These features coupled with the unit's compact size help make set-up and installation simple.
Features
  • Designed for Hazardous Environments
  • Vibration Resistant
  • Explosion-proof
  • Weatherproof and intrinsically Safe

Models matching criteria: 2
DWYER Current to Pressure Transducer, 4-20 mA Input, 6-30 psig (0.4-2.1 bar) Output. view more
  • Input - 4-20 mA
  • Output Pressure - psi: 6 to 30 (kPa: 40 to 200, bar: 0.4 to 2)
50+ In Stock
$850.00 CAD
Does not ship to OH, United States
DWYER Current to Pressure Transducer, 4-20 mA Input, 3-15 psig (0.2-1.0 bar) Output. view more
  • Input - 4-20 mA
  • Output Pressure - psi: 3 to 15 (kPa: 20 to 100, bar: 0.2 to 1)
25+ In Stock
$1,073.00 CAD
Does not ship to OH, United States

Specifications

Accuracy

  • ± 0.1 % of Span

Air Consumption

  • 0.05 scfm (0.85 m³/hour) at Midrange Typical

Approvals & Certifications

  • CE
  • CSA
  • FM

Deadband

  • 0.02 % of Span

Electrical Connectors

  • 1/2” NPT Female

Enclosure, Body Material

  • Chromate-Treated Aluminum with Epoxy Paint

Environmental Protection

  • Class 1, Div. 1, Groups B, C, D
  • Class 1, Div. II Groups A, B, C, D
  • Class I, II, & III, Div. 1, Groups C, D, E, F, G, T4
  • Class I, Zone 0, Group IIB, T4
  • Class II, & III, Div. 2, Groups F & G
  • Class II, Div. 1, Groups E, F, G
  • Dust Ignition-Proof
  • Explosion-proof
  • Intrinsically Safe
  • IP66
  • NEMA 4X
  • Weatherproof

Filter

  • 40 microns

Flow Capacity

  • 4.5 to 12 scfm (7.56 to 20.52 m³/hour) at psig: 25 to 100 (kPa: 170 to 690, bar: 1.7 to 6.9) - Output Capacity

Hysteresis

  • ± 0.1 % of Span

Input Signal

  • 4-20 mA

Media

  • Clean Dry Air Filtered to 40 microns
  • Oil Free

Mounting

  • Bracket

NPT Connection

  • 1/4” NPT Female - Pressure Connection

Operating Temperature

  • -40° to 71° C (-40° to 160° F)

Output

  • psig: 3 to 30 (kPa: 20.7 to 206.8, bar: 0.2 to 2.1)

Power Requirement

  • Loop Powered

Pressure Range

  • bar: 0.3 to 6.9
  • kPa: 34.5 to 700
  • psig: 5 to 100

Pressure Type

  • Gauge

Repeatability

  • ± 0.1 % of Span

Storage Temperature

  • -40° to 93° C (-40° to 200° F)

Supply Pressure

  • psig: 5 to 100 (kPa: 34.47 to 689.5, bar: 0.3 to 6.9) - Air Supply

  • Controlling valve actuators, pneumatic valve positioners, air cylinders, clutches, brakes, dampers, louvers and pumps
show more