6180 AeroDAQ Secure Graphic Recorder for AMS2750D

Brand: Eurotherm

The 6180 AeroDAQ is designed to meet the specifications of the aerospace industry. 

Automated scheduling of TUS (Temperature Uniformity Survey), SAT (System Accuracy Test), and instrument calibration is handled by the AeroDAQ based on furnace class and instrument type as per the relevant tables of AMS2750D.

A Service Page clearly displays the number of days until the next activity is due with messages to alert that the due date is approaching.
Features
  • Colour touchscreen display
  • USB 'plug and play'
  • 6 universal Inputs
  • 32 MB non-volatile flash memory
  • 125 ms parallel sampling
  • Compact flash
  • Modbus RTU
  • Ethernet TCP/IP
  • Web server
  • EtherNet/IP server
  • Multi-language support (Including Chinese, Korean and Cyrillic)

Specifications

Approvals & Certifications

  • CE
  • EMC
  • Emissions & Immunity: BS EN 61326
  • IEC 584.1, 751
  • UL (C): E57766

Cable Length

  • Ethernet Communication: Max.

Channels

  • 0 to 48
  • Maths, Totalisers & Counters: 36 to 128 Virtual Channels
  • Virtual Channels: 36

Circuit Protection

  • Open Circuit Detection: ± 57 NA, Max.
  • Over Voltage Protection (OVP)

Cold Junction Reference

  • External
  • Internal
  • Off
  • Remote

Communication

  • 2 USB Ports at Rear
  • ASCII Protocol
  • BOOTP
  • DHCP
  • EtherNet/IP Server
  • FTP
  • ICMP
  • IEEE 802.3
  • Modbus RTU Master & Slave
  • SMTP
  • SNTP
  • TCP/IP Protocols
  • Transmission Standard: EIA-232
  • Transmission Standard: EIA-485

Current

  • Bias Current: 0.05 NA
  • Maximum

Display

  • Size & Resolution: XGA (1024 x 768 Pixels) 12.1”
  • TFT Color LCD with Cold Cathode Backlight

Electrical Connectors

  • CAT5 Cable
  • Termination: RJ45

Electrical Rating

  • Output: 2 A at 250 V, 500 VA

Environmental Protection

  • Bezel & Display: IP66
  • Sleeve: IP20

Humidity

  • Operation: 5 to 80 % Relative Humidity
  • Storage: 5 to 90 % Relative Humidity

Input

  • -150 mV to 20 V
  • -20 to 20 Vdc Thermocouples Dc mV
  • Channel to Channel: 2,500 Vac (Dielectric Strength)
  • Channel to Ground: 1,500 Vac (Dielectric Strength)
  • Input/Relay Output Sample Rate: 10 Hz
  • Maximum
  • Potentiometer

Input Impedance

  • 20 V Range: 65.3 kiloohms
  • 38 mV, 150 mV, 1 V Ranges: > 10 megaohms

Insulation

  • Terminals to Ground: 50 Vrms or Dc (Basic Insulation)

Insulation Resistance

  • > 10 megaohms at 500 Vdc

Isolation

  • Channel to Channel, Channel to Ground, Relay to Relay, Relay to Ground: 300 Vrms (Double, Basic Insulation)

Linearization

  • RTD Typical of, Max.
  • Thermocouple Typical of, Max.

Mounting

  • Panel Mount DIN 43700

Operating Temperature

  • 0° to 50° C (32° to 122° F)

Power

  • Maximum

Power Requirement

  • Low Voltage Option: 20-42 Vrms, 45 to 400 Hz
  • Low Voltage Option: 20-54 Vdc
  • Poly-Carbonmonofluoride / Lithium Batteries

Power Supply

  • 20-42 Vac (20-54 Vdc)
  • 90-264 Vac (110-370 Vdc) 47 to 63 Hz

Resistance

  • Input (Min. Break Resistance): 10 megaohms
  • Input: 0 to 600 ohms
  • Shunt Value: 100 to 250 ohms

Resolution

  • Input: 1.4 to 720 µV
  • Input: 5 to 148 milliohms

RTD Type

  • Cu10
  • Cu53
  • JPt100
  • Ni100
  • Ni120
  • Pt100
  • Pt1000
  • Pt100A

Sensor, Probe Connection

  • 2-Wire RTD
  • 3-Wire RTD

Sensor, Probe Type

  • B Thermocouple
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • G2 Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • Ni/NiMo Thermocouple
  • NiMo/NiCo Thermocouple
  • N Thermocouple
  • PL2 Thermocouple
  • R Thermocouple
  • S Thermocouple
  • T Thermocouple
  • U Thermocouple

Shock

  • BS EN 61010

Storage Temperature

  • -20° to 60° C (-4° to 140° F)

Supply Voltage

  • 110-370 Vdc
  • 85-265 Vac, 47 to 63 Hz

Temperature Effect

  • Worst Case Temperature Performance Input Per °C: 25 to 388 ppm

Temperature Range

  • RTD Typical: -220° to 850° C (-364° to 1,562° F)
  • Thermocouple Typical: -270° to 2,495° C (-454° to 4,523° F)

Vibration

  • (10 to 150 Hz), BS EN 60873

Voltage

  • Maximum
  • The Rate Impulse Voltage for Equipment on Nominal 230 V Mains is 2,500 V