Brand: Dwyer Instruments, LLC

The Series UFB Ultrasonic Flowmeter Set utilizes the transit-time difference for measuring flow rates in pipes non-invasively.

This is the permanent model, allowing the user to mount the converter on a surface or pipe. 

The easy-to-use compact and lightweight design is intended for mechanical devices using ideally homogeneous liquids that contain no air pockets.

The Series UFB comes with a sturdy IP65 rating, protecting it from dust and direct water contact.

The Series UFB has 4 to 20 mA and pulse output capabilities.
Features
  • Non-Invasive Pipe Measurement
  • Easy-to-Use compact and lightweight design, intended for homogeneous liquids that contain no air
  • Simple installation with all necessary components included such as converter, Sensor, Cables and Mounting Accessories
  • Sturdy IP65 Rating, protecting it from dust and direct water contact

Models matching criteria: 8
DWYER Complete Ultrasonic Flowmeter Set, Pipe Size Range 0.5 to 4.5" (13 to 115 mm), 24 VAC/VDC Power Supply. view more
  • Pipe Size - 0.5" to 4.5" (13 to 115 mm)
  • Power Supply - 24 Vac/dc
  • Certificates - No Additional Certificate
100+ In Stock
$245.00 CAD
Does not ship to OH, United States
  • Pipe Size - 0.5" to 4.5" (13 to 115 mm)
  • Power Supply - 24 Vac/dc
  • Certificates - NIST Traceable Calibration Certificate
100+ In Stock
$252.00 CAD
Does not ship to OH, United States
  • Pipe Size - 2" to 79" (50 to 2000 mm)
  • Power Supply - 86 to 264 Vac
  • Certificates - NIST Traceable Calibration Certificate
100+ In Stock
$1,628.00 CAD
Does not ship to OH, United States
  • Pipe Size - 0.5" to 4.5" (13 to 115 mm)
  • Power Supply - 86 to 264 Vac
  • Certificates - NIST Traceable Calibration Certificate
50+ In Stock
$92.00 CAD
Does not ship to OH, United States
  • Pipe Size - 2" to 79" (50 to 2000 mm)
  • Power Supply - 24 Vac/dc
  • Certificates - NIST Traceable Calibration Certificate
50+ In Stock
$1,773.00 CAD
Does not ship to OH, United States
DWYER Complete Ultrasonic Flowmeter Set, Pipe Size Range 2 to 79" (50 to 2000 mm), 24 VAC/VDC Power Supply. view more
  • Pipe Size - 2" to 79" (50 to 2000 mm)
  • Power Supply - 24 Vac/dc
  • Certificates - No Additional Certificate
25+ In Stock
$596.00 CAD
Does not ship to OH, United States
DWYER Complete Ultrasonic Flowmeter Set, Pipe Size Range 2 to 79" (50 to 2000 mm), 86 to 264 VAC Power Supply. view more
  • Pipe Size - 2" to 79" (50 to 2000 mm)
  • Power Supply - 86 to 264 Vac
  • Certificates - No Additional Certificate
25+ In Stock
$2,075.00 CAD
Does not ship to OH, United States
DWYER Complete Ultrasonic Flowmeter Set, Pipe Size Range 0.5 to 4.5" (13 to 115 mm), 86 to 264 VAC Power Supply. view more
  • Pipe Size - 0.5" to 4.5" (13 to 115 mm)
  • Power Supply - 86 to 264 Vac
  • Certificates - No Additional Certificate
25+ In Stock
$748.00 CAD
Does not ship to OH, United States

Specifications

Accuracy

  • ± 0.5 to ± 2 % of Flow Reading of Flow Rate > 0.03 ft/sec (0.01 m/sec) & Pipe O.D. > 3.0” (75 mm)
  • ± 3 % of Flow Reading for Flow Rate > 0.03 ft/sec (0.01 m/sec) & Pipe O.D. 0.5 to 3” (13 to 75 mm)
  • ± 6 % of Flow Reading for Flow Rate < 0.03 ft/sec (0.01 m/sec)

Approvals & Certifications

  • CE

Consumption

  • 10.5 W

Display

  • 240 x 64 Pixel Graphic Display High Contrast Black on White with Backlight
  • 5” W x 1.3” H (5 x 33.02 mm)

Electrical Connectors

  • Removable Screw-in Typical Terminal Block

Environmental Protection

  • IP54
  • IP65

Input

  • TNC Cable from Sensors

Loop Resistance

  • 620 ohms, Max.

Materials of Construction

  • ABS Plastic
  • Aluminum

Media

  • Liquids & Gases

Mounting

  • Wall Mounted

NACE & NIST

  • NIST Traceable Calibration Certificate

Output

  • 0 to 16 mA
  • 0-20 mA
  • 0 to 26 mA
  • 4-20 mA
  • 48 V at 500 mA - Max.
  • Pulse Width - 2 to 500 ms

Pipe Size

  • 0.5” to 79” (13 to 2,000 mm)

Power Requirement

  • 1 A, Max.
  • 240 Vac/Vdc
  • 50/60 Hz
  • 86-264 Vac

Repeatability

  • ± 0.5 % of Measured Value or 0.03 ft/sec (0.01 m/sec)

Response Time

  • < 500 milliseconds

Temperature Range

  • -20° to 135° C (-4° to 275° F) - Transducer

  • Treated Water
  • River Water
  • Sea Water
  • Potable Water
  • Demineralized Water
  • Glycol / Water Mix
  • Hydraulic System
  • Diesel Oil
  • Flow Rate